Closing one door set opens the adjacent one.
The door is pushed open by displaced air. Separate the cabinet segments with a central wall flush with the corpus or provide ventilation (e. g. in the rear wall).
-
WingLine L
Closing one door set opens the adjacent one.
The door is pushed open by displaced air. Separate the cabinet segments with a central wall flush with the corpus or provide ventilation (e. g. in the rear wall).
-
WingLine L
The door can not be closed all the way.
1. Solution approach
The running component is knocking against the carcase side as the cup distance for the cup drilling is too small.
- The cup distance for the cup drilling is 5.0 mm.
2. Solution approach
The running and guide profiles are not mounted parallel to the upper and lower floor.
- The profiles must be mounted in parallel with the mounting aid.
3. Solution approach
Due to strong deflection of the door, the door edge strikes against the side of the carcase.
- Door deflectors or door clamps are recommended.
-
WingLine L
The door can not be closed all the way.
1. Solution approach
The running component is knocking against the carcase side as the cup distance for the cup drilling is too small.
- The cup distance for the cup drilling is 5.0 mm.
2. Solution approach
The running and guide profiles are not mounted parallel to the upper and lower floor.
- The profiles must be mounted in parallel with the mounting aid.
3. Solution approach
Due to strong deflection of the door, the door edge strikes against the side of the carcase.
- Door deflectors or door clamps are recommended.
-
WingLine L
The door does not close by itself on the last few millimetres.
Hinges with self closing feature must be used.
-
WingLine L
The door does not close by itself on the last few millimetres.
Hinges with self closing feature must be used.
-
WingLine L
The door does not open all the way.
1. Solution approach
- The cabinet is not in the scale and must be aligned.
- The doors must be aligned.
- The doors are aligned, but the hinges are under tension. Make sure that the joint front to body is even.
2. Solution approach
The running and guide profiles are not mounted parallel to the upper and lower floor.
- The profiles must be mounted in parallel with the mounting aid.
3. Solution approach
The door has been lowered too far by height adjuster, making guide component scrape on profile.
4. Solution approach
The central hinge has been mounted incorrectly or the pivot point offset is not correct.
- Mount the central hinge according to the assembly instructions.
5. Solution approach
Door damper not shortened for full overlay.
- Shorten the door damper
-
WingLine L
The door does not open all the way.
1. Solution approach
- The cabinet is not in the scale and must be aligned.
- The doors must be aligned.
- The doors are aligned, but the hinges are under tension. Make sure that the joint front to body is even.
2. Solution approach
The running and guide profiles are not mounted parallel to the upper and lower floor.
- The profiles must be mounted in parallel with the mounting aid.
3. Solution approach
The door has been lowered too far by height adjuster, making guide component scrape on profile.
4. Solution approach
The central hinge has been mounted incorrectly or the pivot point offset is not correct.
- Mount the central hinge according to the assembly instructions.
5. Solution approach
Door damper not shortened for full overlay.
- Shorten the door damper
-
WingLine L
The door only opens by a few millimetres.
The running component is knocking against the carcase side as the cup distance for the cup drilling is too small. The cup distance for the cup drilling is 5.0 mm.
-
WingLine L
The door only opens by a few millimetres.
The running component is knocking against the carcase side as the cup distance for the cup drilling is too small. The cup distance for the cup drilling is 5.0 mm.